vexilla_paginae

Haemoclip Endoscopica Disposable ad Endoscopiam MDR CE Approbata

Haemoclip Endoscopica Disposable ad Endoscopiam MDR CE Approbata

Descriptio Brevis:


Detalia Producti

Etiquettae Productarum

Detalia Producti

● Accurata et Flexibilis Positionis Efficacia

● Alta ratio successus in vulneribus claudendis

● EO sterilis et ad usum paratus

● Lata Compatibilitas Clinica

1
Duo
Tres
quattuor

Applicatio:

Ad haemostasis in proceduris endoscopicis gastrointestinalibus adhibitus.

quinque
VIII

Specificatio

Modellum

Magnitudo Aperturae Fibulae

(mm)

Longitudo Operativa

(mm)

Canalis Endoscopicus

(mm)

Characteres

ZRH-HCA-165-10

10

1650

≥2.8

Ad Gastroscopiam

Obductus

ZRH-HCA-165-12

12

1650

≥2.8

ZRH-HCA-165-15

15

1650

≥2.8

ZRH-HCA-165-17

17

1650

≥2.8

ZRH-HCA-195-10

10

MCML

≥2.8

Ad gastrointestinalia

ZRH-HCA-195-12

12

MCML

≥2.8

ZRH-HCA-195-15

15

MCML

≥2.8

ZRH-HCA-195-17

17

MCML

≥2.8

ZRH-HCA-235-10

10

2350

≥2.8

Ad Colonoscopiam

ZRH-HCA-235-12

12

2350

≥2.8

ZRH-HCA-235-15

15

2350

≥2.8

ZRH-HCA-235-17

17

2350

≥2.8

Quaestiones Frequentes

Ex ZRH med.

Tempus Productionis: 2-3 hebdomades post solutionem acceptam, secundum quantitatem ordinis tui

Modus Traditionis:
1. Expresso: Fedex, UPS, TNT, DHL, SF express 3-5 dies, 5-7 dies.
2. Via: Domestica et vicina: dies 3-10
3. Per Mare: 5-45 dies toto orbe terrarum.
4. Aere: 5-10 dies toto orbe terrarum.

Portus Onus:
Shenzhen, Yantian, Shekou, Hong Kong, Xiamen, Ningbo, Shanghai, Nanjing, Qingdao
Secundum postulationem tuam.

Conditiones traditionis:
EXW, FOB, CIF, CFR, C&F, DDU, DDP, FCA, CPT

Documenta Transportationis:
B/L, Factura Mercatoria, Index Sarcinarum

● Magnitudines aperturarum multiplices ad adaptationem totius scenarii.

● Caput fibulae 360° rotabile cum aperitione et clausione iterum adhibenda.

6(1)

● Usus sterilis semel destinatus cum effusione spontanea.

● Haemostasis instantanea et certa, periculum haemorrhagiae tardae minuens.

VII

● Materia biocompatibilis irritationem textuum minimam efficit et reactionem inflammatoriam postoperativam minuit.

● Certificationes completae ad mercatum globalem accedendum.

VIII

Usus Clinicus

Haemoclip intra tractum gastrointestinalem (GI) ad haemostasis efficiendam poni potest:

Defectus mucosi/submucosi < 3 cm
Ulcera sanguinantia, arteriae < 2 mm
Polypi minus quam 1.5 cm diametro
Diverticula in #colo

Haec fibula adhiberi potest ut methodus supplementaria ad claudendas perforationes luminales tractus gastrointestinalis < 20 mm vel ad notationem #endoscopicam.

IX

  • Praecedens:
  • Deinde: